Skip to main content
You can start a project from an existing signal or bring one into the open project using Menu → Import (Ctrl+I). The importer also recognizes Oryx PDFs with an embedded project, if you have one. An ordinary PDF, or one without that attachment, cannot be turned into a signal. Signal PDF export currently appears as Coming soon.

Create a project from a file

  1. Open Menu → New.
  2. Choose From an image or From a file.
  3. For a file exported by Oryx, choose Oryx format in the next window; for instrument TXT or CSV, choose Equipment data. Then select or drag in the file. You can also paste it with Ctrl+V.
  4. Review the preview and confirm. Oryx opens the result in the detected digital or analog mode.
  5. Check the channels and edges or points before saving. A noisy image or unclear scale may need correction.

Images, photos or screenshots

Select the image, photo or screenshot you want to convert as Main. Add Auxiliary images, photos or screenshots if they show the same signal at another zoom level; they help the converter read details. Only the main image is imported as the signal. You can change the main image before continuing.

Data files

The file needs time in the first column, in increasing order, and at least one channel column. Review these options:

Import into the open project

  1. Open Menu → Import and choose an image or file.
  2. Under How it enters, choose Replace all or Paste.
  3. For Paste, enter the starting pulse and target channels. You can mark the pulse on the signal.
  4. Select the file and confirm the result.
Replace all substitutes the open project’s signal and channels and cannot be undone. Save a copy first if you want to keep the previous state. Paste places imported channels into your chosen targets starting at the specified pulse. The open project keeps its mode: an analog signal cannot enter a digital project. A digital signal can be represented as an analog trace when imported into analog mode.

Limits and common errors

Images and instrument data use the converter and are subject to daily plan limits. Oryx files are read locally; they count toward the file limit on Basic and Plus, and do not count on Pro.
  • If data is missing, check that the first column is time and that at least one numeric channel exists.
  • For a long signal, set a Time window and import again.
  • If you reached the daily limit, open Projects → View usage to inspect the previous 24 hours.
  • If the converter cannot be reached, check your network and try again. Failed imports do not count toward the daily limit.